<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Acoustical Society of Iran</title>
<title_fa>مجله انجمن علوم صوتی ایران (مهندسی صوتیات سابق)</title_fa>
<short_title>مجله انجمن علوم صوتی ایران (مهندسی صوتیات سابق)</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://joasi.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2345-5748</journal_id_issn>
<journal_id_issn_online>2345-5748</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>محاسبه‌ی شبه‌سنج‌های بهینه‌ی فراصدا به‌منظور کاهش ابعاد لخته خون در رگ (مقاله پژوهشی)</title_fa>
	<title>Evaluating optimal ultrasound to deform the blood clot in a vessel (Research Article)</title>
	<subject_fa>عمومی</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:IRANyekan;&quot;&gt;&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;در این مقاله، هدف، به&#8204;دست آوردن شبه&#8204;سنج&#8204;های بهینه&#8204;ی امواج فراصدا به&#8204;منظور تغییر شکل و کاهش ابعاد لخته&#8204;ی خون در رگ است. با توجه به ارتباط مستقیم فشار ناشی از فروریزش حباب&amp;shy;&#8204;های ایجادشده در اثر امواج فراصدا با شدت امواج، تعیین بهینه&#8204;&amp;shy;ی شدت امواج فراصدا از اهمیت بالایی برخوردار است. بدین منظور فشار فروریزش حباب با استفاده از معادله ریلی-&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;پلست (&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;آرپی&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;) محاسبه شده است. علاوه بر این، فشار مورد نیاز برای تغییر شکل لخته&#8204;ی خون محاسبه می&#8204;&amp;shy;گردد. به منظور محاسبه&#8204;ی فشار لازم برای تغییر شکل لخته&#8204;، شبیه&#8204;سازی توأمان جریان و ساختار لخته با استفاده از معادلات کامل ناویر-&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;FA&quot; style=&quot;font-size:11.0pt&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;استوکس که بر میدان جریان خون حاکم است و معادلات گسسته خطی شده برای محیط لخته انجام می&#8204;شود. با استفاده از شبه&#8204;سنج&#8204;های به&#8204;دست&#8204;آمده برای کمینه تپ (پالس) فشاری لازم برای از هم گسیختن شکل لخته و شدت فراصدای لازم به منظور ایجاد کمینه فشار، شبیه&#8204;&amp;shy;سازی&#8204;&amp;shy;ها صورت گرفته و نشان داده شده که لخته در مواجهه با فشار اعمالی تغییر شکل خواهد داد که مؤید اثربخشی روش پیشنهادی است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;
&lt;br&gt;
&lt;span style=&quot;font-family:IRANyekan;&quot;&gt;&amp;nbsp;&lt;/span&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;The goal of the present paper is to gain an optimal intensity of ultrasound to achieve required pressure field generated by the collapsing bubble in blood to break down blood clots. Due to the direct relationship between the pressure caused by the collapse of bubbles caused by ultrasound and the intensity of the waves, determining the optimal intensity of the ultrasound is of great importance. For this purpose, the collapse pressure within the bubble has been calculated using Rayleigh&amp;ndash;Plesset (RP) equation. Moreover, &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;&lt;span style=&quot;letter-spacing:.25pt&quot;&gt;a coupling simulation of the flow and clot structure is performed using &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;the &lt;span style=&quot;letter-spacing:.25pt&quot;&gt;full Navier-Stokes &lt;/span&gt;equations,&lt;span style=&quot;letter-spacing:.25pt&quot;&gt; which governs the blood domain, &lt;/span&gt;and linearized discrete equations for the clot medium &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:11.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; style=&quot;font-family:&quot; times=&quot;&quot;&gt;to calculate the desired bubble collapsing pressure necessary to break down the clots, which has immense importance in medical applications. Using the obtained parameters for the minimum pressure pulse required to deform the clot and the ultrasound intensity required to create the minimum pressure, simulations have been performed and it has been shown that the clot&amp;rsquo;s shape changes when confronted with the the applied pressure which confirms the effectiveness of the proposed method.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>امواج فراصدا, دینامیک حباب, فشار فروریزش, شبیه‌سازی سه- بعدی, لخته‌ی خون.</keyword_fa>
	<keyword>Ultrasound, Bubble dynamic, Collapsing pressure, 3D CFD, Blood clot deformation.</keyword>
	<start_page>73</start_page>
	<end_page>83</end_page>
	<web_url>http://joasi.ir/browse.php?a_code=A-10-1153-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Azadegan</last_name>
	<suffix></suffix>
	<first_name_fa>معصومه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>آزادگان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m.azadegan@khatam.ac.ir</email>
	<code>0080599941</code>
	<orcid>10031947532846004052</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Khatam University</affiliation>
	<affiliation_fa>دانشگاه خاتم</affiliation_fa>
	 </author>


	<author>
	<first_name>Ramin</first_name>
	<middle_name></middle_name>
	<last_name>Kamali Moghaddam</last_name>
	<suffix></suffix>
	<first_name_fa>رامین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کمالی مقدم</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>rkamali@ari.ac.ir</email>
	<code>10031947532846004053</code>
	<orcid>10031947532846004053</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>A&amp;S Research Institute</affiliation>
	<affiliation_fa>پژوهشگاه هوا و فضا</affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Najafi</last_name>
	<suffix></suffix>
	<first_name_fa>محمود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نجفی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mnajafi@kent.edu</email>
	<code>10031947532846004054</code>
	<orcid>10031947532846004054</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Kent State University</affiliation>
	<affiliation_fa>دانشگاه ایالتی کنت</affiliation_fa>
	 </author>


	<author>
	<first_name>N.</first_name>
	<middle_name></middle_name>
	<last_name>Sahranavard Fard</last_name>
	<suffix></suffix>
	<first_name_fa>نسرین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صحرانوردفرد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>nasrinfard95@gmail.com</email>
	<code>10031947532846004055</code>
	<orcid>10031947532846004055</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Perugia</affiliation>
	<affiliation_fa>دانشگاه پروجا ایتالیا</affiliation_fa>
	 </author>


	<author>
	<first_name>M. </first_name>
	<middle_name></middle_name>
	<last_name>Mokhtari Dizaji</last_name>
	<suffix></suffix>
	<first_name_fa>منیژه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مختاری دیزجی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mokhtarm@modares.ac.ir</email>
	<code>10031947532846004056</code>
	<orcid>10031947532846004056</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Tarbiat Modares University</affiliation>
	<affiliation_fa>دانشگاه تربیت مدرس</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
